Concrete Mix Design Calculation
Concrete mix |
Mix Design:-
Concrete
mix design is the process of finding right proportions of cement, sand and
aggregates for concrete to achieve target strength in structures. So, concrete
mix design can be stated as Concrete Mix = Cement:Sand:Aggregates.
The concrete mix design
involves various steps, calculations and laboratory testing to find right mix
proportions. This process is usually adopted for structures which requires
higher grades of concrete such as M25 and above and large construction projects
where quantity of concrete consumption is huge.
Benefits:-
Benefits of concrete mix
design is that it provides the right proportions of materials, thus making the
concrete construction economical in achieving required strength of structural
members. As, the quantity of concrete required for large constructions are
huge, economy in quantity of materials such as cement makes the project
construction economical.
Mix Design can be calculated for Higher grade of Concrete like M20, M25, M30 and above.
Data Required for Concrete
Mix Design
(i)
Concrete Mix Design Stipulation
(a)
Characteristic compressive strength required in the field at 28 days grade
designation - M25
(b)
Nominal maximum size of aggregate - 20 mm
(c) Shape
of CA - Angular
(d)
Degree of work ability required at site -50 to 75 mm (slump)
(e)
Degree of quality control available at site - As per IS:456
(f) Type
of exposure the structure will be subjected to (as defined in IS: 456) - Mild
(g) Type
of cement: PSC conforming IS:455
(h)
Method of concrete placing: pump able concrete
(ii) Test data of
material (Should be determined in the laboratory)
(a)
Specific gravity of cement - 3.15
(b)
Specific gravity of FA - 2.64
(c)
Specific gravity of CA -2.84
(d)
Aggregate are assumed to be in saturated surface dry condition.
(e) Fine
aggregates confirm to Zone II of IS - 383
Procedure for Concrete
Mix Design of M25 Concrete:-
Step 1 — Determination Of
Target Strength
Hims worth constant for 5% risk factor is 1.65. In this case standard deviation is taken
from IS:456 against M 20 is 4.0.
ftarget = fck +
1.65 x S
= 25 +
1.65 x 4.0 = 31.6 N/mm2
Where,S = standard deviation in N/mm2 = 4 (as
per table -1 of IS 10262- 2009)
Step 2 — Selection of
water / cement ratio:-
From Table 5 of IS 456, (page no 20)
Maximum
water-cement ratio for Mild exposure condition = 0.55
Based on
experience, adopt water-cement ratio as 0.5.
0.5<0.55, Hence Ok.
Step 3 — Selection of
Water Content
From
Table 2 of IS 10262- 2009,
Maximum
water content = 186 Kg (for Nominal maximum size of aggregate — 20 mm)
Table for Correction in water content
Parameters
|
Values as per Standard reference
condition
|
Values as per Present Problem
|
Departure
|
Correction in Water Content
|
Slump
|
25-50 mm
|
50-75
|
25
|
(+3/25) x 25 = +3
|
Shape of Aggregate
|
Angular
|
Angular
|
Nil
|
–
|
Total
|
+3
|
Estimated water content = 186+ (3/100) x 186 = 191.6 kg /m3
Step 4 — Selection of
Cement Content
Water-cement
ratio = 0.5
Corrected water content = 191.6 kg /m3
Cement
content =
From
Table 5 of IS 456,
Minimum cement Content for mild exposure condition = 300 kg/m3
383.2 kg/m3 > 300 kg/m3, hence,
OK.
This
value is to be checked for durability requirement from IS: 456.
In the present example against mild exposure and for the case of
reinforced concrete the minimum cement content is 300 kg/m3 which
is less than 383.2 kg/m3. Hence cement content
adopted = 383.2 kg/m3.
As per
clause 8.2.4.2 of IS: 456 Maximum cement content = 450 kg/m3.
Step 5: Estimation of
Coarse Aggregate proportion:-
From
Table 3 of IS 10262- 2009,
For
Nominal maximum size of aggregate = 20 mm,
Zone of
fine aggregate = Zone II
And For
w/c = 0.5
Volume of
coarse aggregate per unit volume of total aggregate = 0.62
Table for correction in estimation of coarse aggregate proportion
Parameter
|
Values as per Standard reference
condition
|
Values as per present problem
|
Departure
|
Correction in Coarse Aggregate
proportion
|
Remarks
|
W/c
|
0.5
|
0.5
|
Nil
|
–
|
See Note 1
|
Workability
|
–
|
pump able concrete
|
–
|
-10%
|
See Note 2
|
Total
|
-10%
|
Note 1: For every ±0.05 change in w/c, the coarse aggregate proportion is
to be changed by 0.01. If the w/c is less than 0.5 (standard value), volume of
coarse aggregate is required to be increased to reduce the fine aggregate
content. If the w/c is more than 0.5,
volume of coarse aggregate is to be reduced to increase the fine
aggregate content. If coarse aggregate is not angular, volume of coarse
aggregate may be required to be increased suitably, based on experience.
Note 2: For
pump able concrete or congested reinforcement the coarse aggregate proportion
may be reduced up to 10%.
Therefore,
Volume of
coarse aggregate per unit volume of total aggregate = 0.62 x 90% = 0.558
Volume of
fine aggregate = 1 – 0.558 = 0.442.
Step 6: Estimation of the
mix ingredients
a) Volume of concrete = 1 m3
b) Volume
of cement = (Mass of cement / Specific gravity of cement) x (1/1000)
= (383.2/3.15) x (1/1000) = 0.122 m3
c) Volume
of water = (Mass of water / Specific gravity of water) x (1/1000)
= (191.6/1) x (1/1000) = 0.1916 m3
d) Volume of total aggregates = a – (b + c ) = 1 – (0.122 +
0.1916) = 0.6864 m3
e) Mass of coarse aggregates = 0.6864 x 0.558 x 2.84 x 1000 =
1087.75 kg/m3
f) Mass of fine aggregates = 0.6864 x 0.442 x 2.64 x 1000 = 800.94
kg/m3
Concrete Mix proportions
for Trial Mix 1
Cement = 383.2 kg/m3
Water = 191.6 kg/m3
Fine aggregates = 800.94 kg/m3
Coarse aggregate = 1087.75 kg/m3
W/c = 0.5
For trial
-1 casting of concrete in lab, to check its properties.
It will
satisfy durability & economy.
For
casting trial -1, mass of ingredients required will be calculated for 4 no’s
cube assuming 25% wastage.
Volume of concrete required for 4 cubes = 4 x (0.153 x1.25) =
0.016878 m3
Cement = (383.2 x 0.016878) kg/m3 =
6.47 kg
Water = (191.6 x 0.016878) kg/m3 =3.23
kg
Coarse aggregate = (1087.75 x 0.016878) kg/m3 =18.36
kg
Fine aggregates = (800.94 x 0.016878) kg/m3 = 13.52
kg
Step 7: Correction due to
absorbing / moist aggregate:-
Since the
aggregate is saturated surface dry condition hence no correction is required.
Step 8: Concrete Trial
Mixes:-
Concrete Trial Mix 1:
The mix
proportion as calculated in Step 6 forms trial mix1. With this proportion,
concrete is manufactured and tested for fresh concrete properties requirement i.e.
workability, bleeding and finishing qualities.
In this
case,
Slump
value = 25 mm
Compaction
Factor = 0.844
So, from
slump test we can say,
Mix is
cohesive, workable and had a true slump of about 25 mm and it is free from
segregation and bleeding.
Desired
slump = 50-75 mm
So
modifications are needed in trial mix 1 to arrive at the desired workability.
Concrete Trial Mix 2:
To
increase the workability from 25 mm to 50-75 mm an increase in water content by
+3% is to be made.
The
corrected water content = 191.6 x 1.03 = 197.4 kg.
As
mentioned earlier to adjust fresh concrete properties the water cement ratio
will not be changed. Hence
Cement Content = (197.4/0.5) = 394.8 kg/m3
Which
also satisfies durability requirement.
Volume of all in aggregate = 1 – [{394.8/(3.15×1000)} + {197.4/(1
x 1000)}] = 0.6773 m3
Mass of coarse aggregate = 0.6773 x 0.558 x 2.84 x 1000 = 1073.33
kg/m3
Mass of fine aggregate = 0.6773 x 0.442 x 2.64 x 1000 = 790.3 kg/m3
Concrete Mix Proportions
for Trial Mix 2
Cement = 384.8 kg/m3
Water = 197.4 kg/m3
Fine aggregate =790.3 kg/m3
Coarse aggregate = 1073.33 kg/m3
For
casting trial -2, mass of ingredients required will be calculated for 4 no’s
cube assuming 25% wastage.
Volume of concrete required for 4 cubes = 4 x (0.153 x1.25) =
0.016878 m3
Cement = (384.8 x 0.016878) kg/m3 =
6.66 kg
Water = (197.4 x 0.016878) kg/m3 =3.33
kg
Coarse aggregate = (1073.33 x 0.016878) kg/m3 =18.11
kg
Fine aggregates = (790.3 x 0.016878) kg/m3 = 13.34
kg
In this
case,
Slump
value = 60 mm
Compaction
Factor = 0.852
So, from
slump test we can say,
Mix is
very cohesive, workable and had a true slump of about 60 mm.
It
virtually flowed during vibration but did not exhibit any segregation and
bleeding.
Desired
slump = 50-75 mm
So , it
has achieved desired workability by satisfying the requirement of 50-75 mm
slump value .
Now , we
need to go for trial mix-3 .
Concrete Trial
Mix 3:
In case
of trial mix 3 water cement ratio is varied by +10% keeping water content
constant. In the present example water cement ratio is raised to 0.55 from 0.5.
An
increase of 0.05 in the w/c will entail a reduction in the coarse aggregate
fraction by 0.01.
Hence the
coarse aggregate as percentage of total aggregate = 0.558 – 0.01 = 0.548
W/c =
0.55
Water
content will be kept constant.
Cement content = (197.4/0.55) = 358.9 kg/m3
Hence,
volume of all in aggregate
= 1 – [{(358.9/(3.15 x 1000)} + (197.4/1000)] =0.688 m3
Mass of coarse aggregate = 0.688 x 0.548 x 2.84 x 1000 = 1070.75
kg/m3
Mass of fine aggregate = 0.688 x 0.452 x 2.64 x 1000 = 821 kg/m3
Concrete Mix Proportions
of Trial Mix 3
Cement = 358.9 kg/m3
Water = 197.4 kg/m3
FA = 821 kg/m3
CA = 1070.75 kg/m3
For
casting trial -3, mass of ingredients required will be calculated for 4 no’s
cube assuming 25% wastage.
Volume of concrete required for 4 cubes = 4 x (0.153 x1.25) =
0.016878 m3
Cement = (358.9 x 0.016878) kg/m3 =
6.06 kg
Water = (197.4 x 0.016878) kg/m3 =3.33
kg
Coarse aggregate = (1070.75 x 0.016878) kg/m3 =18.07
kg
Fine aggregates = (821 x 0.016878) kg/m3 = 13.85
kg
In this
case,
Slump
value = 75 mm
Compaction
Factor = 0.89
So, from
slump test we can say,
Mix is
stable, cohesive, and workable and had a true slump of about 75 mm.
Desired
slump = 50-75 mm
So , it
has achieved desired workability by satisfying the requirement of 50-75 mm
slump value .
Now , we
need to go for trial mix-4.
Concrete Trial
Mix 4:
In this
case water / cement ratio is decreased by 10% keeping water content constant.
W/c =
0.45
A
reduction of 0.05 in w/c will entail and increase of coarse aggregate fraction
by 0.01.
Coarse
aggregate fraction = 0.558 +.01 =.568
W/c = 0.45 and water content = 197.4 kg/m3
Cement content = (197.4/0.45) = 438.7 kg/m3
Volume of
all in aggregate
= 1 – [{438.7/(3.15 x 1000)} + (197.4/1000)] = 0.664 m3
Mass of coarse aggregate = 0.664 x 0.568 x 2.84 x 1000 = 1071.11
kg/m3
Mass of fine aggregate = 0.664 x 0.432 x 2.64 x 1000 = 757.28 kg/m3
Concrete Mix Proportions
of Trial Mix 4
Cement = 438.7 kg/m3
Water = 197.4 kg/m3
FA = 757.28 kg/m3
CA = 1071.11 kg/m3
For
casting trial -4, mass of ingredients required will be calculated for 4 no’s
cube assuming 25% wastage.
Volume of concrete required for 4 cubes = 4 x (0.153 x1.25) =
0.016878 m3
Cement = (438.7 x 0.016878) kg/m3 =
7.4 kg
Water = (197.4 x 0.016878) kg/m3 =3.33
kg
Coarse aggregate = (1071.11 x 0.016878) kg/m3 =18.07
kg
Fine aggregates = (757.28 x 0.016878) kg/m3 = 12.78
kg
A local
correction due to moisture condition of aggregate is again applied on this
proportions. With corrected proportions three concrete cubes are cast and
tested for 28 days compressive strength.
A summary
of all the trial mixes is given in the following Table. 111
Recommended mix
proportion of ingredients for grade of concrete M25:
From
Compressive Strength vs. c/w graph for target strength 31.6 MPa we get,
W/c =
0.44
water content = 197.4 kg/m3
Cement content = (197.4/0.44) = 448.6 kg/m3
Volume of
all in aggregate
= 1 – [{448.6/(3.15 x 1000)} + (197.4/1000)] = 0.660 m3
A
reduction of 0.05 in w/c will entail and increase of coarse aggregate fraction
by 0.01.
Coarse
aggregate fraction = 0.558 +.01 =.568
Volume of
fine aggregate = 1 – 0.568 = 0.432
Mass of coarse aggregate = 0.660 x 0.568 x 2.84 x 1000 = 1064.65
kg/m3
Mass of
fine aggregate = 0.660 x 0.432 x 2.64 x 1000 = 752.71 kg/m3
0 Comments
For more Information Please Comment